rheem c7 76 error code Mckenna Washington

Capital Business Machines is a family-owned corporation offering various business products and services. As an authorized Sharp electronics dealer, the company provides customers with a full line of Sharp business products, such as digital copiers and printers, network printers, facsimile machines, and multifunctional copier, printer, fax and scanner combination machines. Its industry-certified network engineers and technicians provide Compaq computer networks and network maintenance services. It also offers personal computers, court recorders, dictation machines, electronic white boards, shredders, projectors, calculators, and various point-of-sale materials. At its computerized dispatch center, the company receives customers service request and schedules technicians to arrive at their businesses. The company provides satellite laptop computers to its technicians so that they are familiar the customer s machine's service history and can order the parts in real-time. Capital Business Machines is located in Olympia, Wash.

Computer Networking Faxing Plotting Printing Sales Scanners Scanning

Address 3660 Pacific Ave SE, Olympia, WA 98501
Phone (253) 442-2102
Website Link http://www.cbm-wa.com
Hours

rheem c7 76 error code Mckenna, Washington

Ohm out sensor. When installing TP, apply 6 wraps teflon tape on threads. Ask an HVAC Expert for Answers Ask an Expert Home Improvement Questions HVAC Questions How JustAnswer Works: Ask an Expert Experts are full of valuable knowledge and are ready to help Ensure gas type and pressure are correct.

Tankless operation overview/ pdf Maintain your water heater/ pdf Maintain water heater 2012/ pdf Removal and cleaning Rheem Tankless burner Paloma use and care Buy flushing system $199 or Buy whole Ohm out sensor. You get new PC Board. Post Reply Re: Tankless remote control error message (Paloma 7.4) Author: frankyb(CA) I called tech support at Paloma/Rheem (866) 369-4786.

Please enter a valid email address. I liked the idea of saving energy too, but our local utility makes that hard to accomplish with a $16/month minimum on the gas bill. characters left:

Contact Us|Terms of Service|Privacy & Security|About Us|Our Network|Sitemap © 2003-2016 JustAnswer LLC JustAnswer UKJustAnswer GermanyJustAnswer SpanishJustAnswer Japan 95 6063059 Search Fixya Press enter to search. The PCB has changed, maybe I'll post the photo of the old and new one.

Yes it's true that tankless use more fuel to heat 1 gallon of water. BUT Rheem promoters say ...tankless computer lasts 20 years. They told me that a flashing 76 is a circuit board failure. The Fedex package included a PRP label to return the old part so they can figure out what went wrong and improve it.

It blows ( 10/25/2016 10/25/2016 Rico_Soma Rodgers intelli vent on my rheem water heater it shows 10/25/2016 10/25/2016 Rico_Soma Sure. The technican diagnosed the problem as the "flow control valve"; he managed to get Rheem/Paloma to cover the part under warranty...I only had to shell out the money for the install. I bought it 3 years ago. Question about Rheem Water Heaters 1 Answer No hot water error codes ...codes can mean PC board failure.

It's a controller error that needs to be fixed by replacing the PCB. We built with this in mind so we didn't have any issues with having a large enough natural gas service to feed this and our furnace at the same time. Add × Loading... Vice President: An expert whose answer got voted for 100 times.

All gas appliances must be properly vented or the combustion by-product can kill. Generally, extension cords do not deliver reliable power without occasional voltage drop. Maximum temperature for Rheem tankless is tepid 120 degrees, using the remote. I had a problem.

Ensure proper venting materials were used. Ask Your Own HVAC Question Share this conversation Related HVAC Questions Question Date Submitted I have a ruud that stop running when i put the heat on it 10/26/2016 10/26/2016 airheatman Tankless troubleshooting resources for homeowner Search this page: Crtl+F Remember, Tankless is a computer that happens to heat water. It was a Saturday and it took over 45 minutes to talk to someone and find out that the package was shipped to the wrong address.

It draws from the surrounding air and pushes the exhaust outside. Rheem Water Heaters hot water service model fix gas cap cover open hot code c7 76 mean top cover gas water tankless water heater model... Maybe lack of required yearly maintenance.Common error codes can be caused by not following maintenance protocol such as cleaning combustion parts, checking gas pressure, checking venting, and air intake, bleeding gas Ensure appliance is properly grounded.

Rheem does not post service manuals. -NO ERROR code? It gives hot water for about 15 sec, then starts flashing C7 12 or C2 11. On commercial water heater, lower setpoint temperature below 180 F at high altitude. 16 Over Temperature Warning Check for clogged heat exchanger. You can't post conmments that contain an email address. × Comment Anonymously Video Images lawdealer Level 1: An expert who has achieved level 1.

Your cache administrator is webmaster. The system returned: (22) Invalid argument The remote host or network may be down. This is funnily enough, the 4th item at home that have had blown caps, that I have replaced myself. Make sure gas meter is large enough to support all the gas appliancesconnected to meter.

Buy: High temperature Tankless condensate drain Resources; Rheem condensate drain /pdf 9 ways to save with water heater Gas line Do not use flexible gas line. Be real. TP can release water when TP valve is defective, and when debris is caught under lever. Model PTG-74XN-2.

Check power supply for proper voltage and voltage drops. For example cleaning burner and flame rod, or replacing bad flame rod, or installing correct gas line, or checking gas pressure etc.Fix any tankless problem yourself, any brand tankless, same day and imagine telling the jury how you believed that spending lota money to buy a computer-chip water heater that requireslarger gas line and larger vent pipe was magically going to supply Ensure you have at least the minimum flow rate required for unit to fire.

You may NOT copy or distribute the content that appears on this site without written permission from Fixya Ltd. © 2005-2015, Fixya, Ltd. You have a few minutes? Buy another one, lol: Tankless water heaters at Amazon Remember, the purpose of the corporation is to remove all employees except those willing to mislead you in exchange for less pay. How can I fix this, We had it for a month now & it worked before. 11 The Gas Shutoff Valve is not opened completely. 12 Gas Service has been interrupted.

All-Star: An expert that got 10 achievements. http://waterheatertimer.org/pdf/Rheem-error-code-C7-76.pdf http://waterheatertimer.org/pdf/Error-code-13.pdf ... Oh that's right, Rheem is one of those people with last name Corporation, so they allowed to lie up folks to get money. Ensure maximum vertical vent length does not exceed allowable limits.

You must use water softener with tankless water heater or parts will fail within 2 years Tankless heat exchanger is prone to scale build-up, and must be delimed each year. Attach 3/4" plastic or metal pipe from TP going downward to within 6" of floor at nearby floor drain. Go without hot water until service technician can figure out problem. I was wondering if anybody has tried installing a flat plastic panto catch the condensate so it evaporates into air?

Cons: Since this model is a large one, it takes a flow of 2/3 of a gallon per minute to turn it on. Copy following link for troubleshoot resources:http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html Mar 20, 2013 | Rheem Paloma PTG-42PVN / RTG2-42PVN... 1 Answer Error Im getting is C8 82 Before calling service tech, copy following link for Because tankless consume more gas to heat one gallon of water as water rushes past in pipe. Fix drips to save money.

Check flame rod for carbon build-up. Also lethargic, unresponsive people. Our dishwasher doesn't draw that much so it never get warm water unless we run something else while it is filling up. (Update - after the PCB change and high altitude To set temperature above 120 degrees requires a service call to change dip switches, adjust water flow and flow sensors How to set Rheem tankless temperature 2012/ pdf How to change